Number
020-EN
Section
General Section
Use
Sector
Other
Function
Fuel additive
Process
Other
Product category
other
Application
Acceleration of combustion process in a disel mixture
Abstract
Elimination of naphtha contained in a combustion accelerator of a hospital laundry boiler in central Madrid which performed dry cleaning of hospital clothes. Union representatives and regional health and safety experts recommended against the use of the accelerator due to its environmental and health risks.
Substituted substances
Naphtha, hydrotreated light
CAS No. 64742-49-0 EC No. 265-151-9 Index No. 649-328-00-1
Chemical group
Kohlenwasserstoffe
Classification: hazard statements
H350 May cause cancer
H340 May cause genetic defects
H304 May be fatal if swallowed and enters airways
Propan-2-ol
CAS No. 67-63-0 EC No. 200-661-7 Index No. 603-117-00-0
Chemical group
Alkohole
Classification: hazard statements
H225 Highly flammable liquid and vapour
H336 May cause drowsiness or dizziness
H319 Causes serious eye irritation
n-Heptane
CAS No. 142-82-5 EC No. 205-563-8 Index No. 601-008-00-2
Chemical group
Kohlenwasserstoffe
Classification: hazard statements
H225 Highly flammable liquid and vapour
H304 May be fatal if swallowed and enters airways
H336 May cause drowsiness or dizziness
H315 Causes skin irritation
H400 Very toxic to aquatic life
H410 Very toxic to aquatic life with long lasting effects
Reliability of information
Evidence of implementation: there is evidence that the solution was implemented and in use at time of publication
Reason substitution
CMR
Other type of alternative
The process was modified. Due to the health risk for workers, the phase of the process that included the use of the product was eliminated.
Hazard Assessment
» Check the Substance Database according to SUBSPORT Screening Criteria (SDSC)
Description of Substitution
The presence of the toxic product was detected during a project developed by the regional union’s (CC.OO.) health and safety department. The union’s safety representatives requested the Safety Data Sheets of the products used for dry cleaning and found out naphtha was among them. The substance was found in a combustion accelerating compound (RJ-10) added to the diesel mixture in laundry boilers. The product wastes were not disposed of adequately. The main purpose of union intervention was the elimination of tetrachloroethylene used as solvent (see case stuory 019), but upon the detection of the toxic combustion accelerator union reps decided to eliminate the specific phase of the process where it was used. Combustion accelerators are unnecessary, especially if they imply health and environmental risks.Description of procedure or technology (including pre-/post-processing)Use of a combustion accelerator in a laundry boiler. The use of an accelerator has been found to be unnecessary and has been eliminated from the process.Way of application: e.g. spraying, dipping, open/closed system etc.Risk management measures (technical, organizational and personal)Risk reduction by alternative: Human health: e.g. more/less safety measures e.g. technical/operational/personal protection measuresReduction of health risks by eliminating a CMR substance.Risk reduction by alternative: Environment: e.g. waste reduced/increasedReduction of environmental risk and elimination of waste associated with the accelerator.
Case/substitution evaluation
Comments To eliminate the hazard – in accordance to the hierarchy of control measures – is the first and most important measure to be sought. Therefore, the ideal solution was achieved when naphta was removed from the process. Advantage or Disadvantage of alternative
Aspect | Advantage/disadvantage to conventional process |
Technical requirements | |
Implementation | Disadvantages: Boiler’s combustion times increased. The employers conveniently accepted the elimination of the product which they did not consider essential for the process.. |
Operational expenses | |
etc. |
State of implementation
In use
Date and place of implementation
Spain
Enterprise using the alternative
Lavandería hospitalaria central de la Comunidad de Madrid
Type of information supplier
User
Contact
Date, reviewed
February 27, 2020